An accurate custom cable assembly quote depends on more than part numbers and estimated quantities. Manufacturers must understand what the assembly connects, how it will be installed, which conditions it must withstand and what inspection, testing and documentation the program requires.
The stronger your request for quotation, or RFQ, the easier it is to compare suppliers and identify differences in materials, tooling, testing and production assumptions.
You do not need every specification finalized before contacting a manufacturer. A complete drawing and bill of material are helpful, but an experienced engineering-supported manufacturer can often begin with a sample, wiring diagram, connector list, photographs or a description of the application.
The key is to distinguish confirmed requirements from details that still need to be developed.
Have a Cable Assembly Project to Quote?
Use XACT’s Cable Assembly Configuration Tool to submit the specifications you know, identify open requirements and upload supporting files for review.
1. Begin With the Application
Start by explaining what the cable assembly will do. A list of connectors and conductor sizes does not tell the manufacturer how the assembly will be used or which failure risks matter most. Two assemblies with similar electrical configurations may require very different construction if one is installed inside protected equipment and the other is exposed to vibration, chemicals, moisture or repeated movement. include:- Equipment or system type
- General function of the assembly
- Installation location
- Indoor or outdoor use
- Protected or exposed installation
- Stationary or moving application
- Expected service lifes
- Accessibility for maintenance or replacement
- Consequences of failure
2. Identify Whether the Design Is New or Existing
Tell the manufacturer whether the RFQ involves:- A new assembly
- A build-to-print production package
- A redesign of an existing assembly
- A replacement for an obsolete product
- A reverse-engineered assembly
- A prototype requiring further development
- A production transfer from another supplier
Starting Without a Production-Ready Drawing?
XACT can review application requirements, existing samples, partial specifications and available design files to help define a manufacturable approach.3. Provide Drawings, Wiring Diagrams or Pinouts
A controlled drawing is one of the most useful RFQ documents because it can define:- Overall assembly length
- Branch lengths and breakout locations
- Connector orientation
- Pin-to-pin wiring
- Wire gauges and conductor colors
- Shielding requirements
- Labels and identification
- Tolerances
- Notes and workmanship requirements
- Drawing revision
- Approval status
- Wiring diagram
- Pinout table
- Hand sketch
- Marked-up photograph
- Connector datasheets
- Equipment schematic
- Existing sample
- Prior supplier drawing
- Installation measurements
4. Include the Bill of Material When Available
A bill of material, or BOM, should identify the approved components and materials used in the assembly.
Relevant entries may include:
- Bulk cable
- Individual wires
- Connectors
- Contacts
- Backshells
- Seals
- Boots
- Terminals
- Splices
- Tubing
- Sleeving
- Braid
- Heat-shrink
- Labels
- Overmolding materials
- Potting compounds
- Fasteners and mounting hardware
For each item, include the manufacturer and part number when required.
Also state whether substitutions are:
- Prohibited
- Allowed with written approval
- Allowed for equivalent commercial components
- Expected to be recommended by the manufacturer
This matters because a lower-cost quote may be based on alternatives that do not match the original specification. Suppliers should not independently replace controlled components without approval.
When a BOM is incomplete, identify any mandatory components and ask the manufacturer to recommend the remaining materials based on the application.
5. Define the Electrical Requirements
Include the electrical characteristics the assembly must support, not just the wire gauge.
Depending on the application, this may include:
- Operating voltage
- Maximum current
- Signal type
- Data or communication protocol
- Frequency range
- Impedance requirements
- Conductor resistance limits
- Shielding requirements
- Grounding approach
- Isolation requirements
- Circuit identification
- High-voltage separation
- Maximum allowable voltage drop
Specify whether power, control and data circuits share the same assembly.
If shielding is required, define what it is intended to protect against and how it should be terminated. “Shielded cable” alone may not establish whether the shield is connected at one end, both ends, through a backshell or through a separate drain conductor.
6. Define the Mechanical Construction
The RFQ should describe how the assembly must fit, route and connect within the equipment.
Include:
- Overall length
- Branch lengths
- Breakout locations
- Length tolerances
- Minimum bend radius
- Connector orientation
- Right-angle or straight exits
- Mounting points
- Clamps or retention features
- Maximum diameter
- Space restrictions
- Pulling or installation constraints
- Required flexibility
- Repeated flexing or torsion
- Minimum strain-relief length
Explain whether the assembly will be installed once and remain stationary or move continuously during operation.
For molded assemblies, provide the available envelope around each connector or breakout. The manufacturer needs enough clearance to develop an overmold that fits the equipment while providing suitable strain relief and protection.
Contextual references:
7. Describe the Operating Environment
Environmental requirements influence cable compounds, connector selection, sealing, protective coverings and validation methods.
Identify expected exposure to:
- High or low temperatures
- Temperature cycling
- Water spray
- Temporary or continuous submersion
- Oil, fuel or hydraulic fluid
- Cleaning chemicals
- Dust and debris
- UV exposure
- Abrasion
- Impact
- Vibration
- Flexing
- Salt fog
- Pressure
- Outdoor weather
- Hazardous locations
Use actual operating ranges or referenced specifications when available.
Avoid vague terms such as:
- Weatherproof
- Waterproof
- Rugged
- Heavy duty
- Chemical resistant
- High temperature
These terms do not establish measurable acceptance criteria. “Waterproof,” for example, could refer to incidental splash exposure or prolonged submersion at a defined depth and duration.
If the requirement is still being developed, describe the real installation conditions and ask the manufacturer what additional information is needed.
Building for a Demanding Environment?
Review XACT’s custom cable assembly capabilities for applications involving overmolding, shielding, environmental protection and ruggedized construction.8. State the Required Workmanship Standards
Identify any workmanship or program standards that must apply.
IPC/WHMA-A-620 establishes requirements and acceptance criteria for cable and wire harness assemblies, including crimped, mechanically secured and soldered interconnections and related assembly activities. It does not replace the need to define the product’s design, inspection frequency, testing and application-specific requirements in the purchasing documentation.
Your RFQ should state:
- Applicable standard and revision
- Required class or acceptance level
- Customer-specific workmanship requirements
- Applicable addenda
- Required operator qualifications
- Inspection requirements
- Source inspection requirements
- Any conflicts between the drawing and referenced standards
Do not list standards simply because they sound relevant. Apply them only when required by the program, customer or product risk.
Buyers should also distinguish a quality-management-system certification from product-specific acceptance requirements. ISO 9001 provides a framework for managing consistent processes and meeting customer and regulatory expectations, but it does not prescribe the design or acceptance criteria for a particular cable assembly.
Related link: View XACT Certifications and Accreditations
9. Define Testing and Validation Requirements
Do not request “100% testing” without defining which tests must be performed.
Possible production or qualification tests include:
- Point-to-point continuity
- Short-circuit detection
- Insulation resistance
- Dielectric withstand
- Contact resistance
- Pull testing
- Functional testing
- Leak or ingress testing
- Flex-cycle testing
- Temperature testing
- Vibration testing
- Signal-integrity testing
- Customer-defined test procedures
State:
- Which tests apply to every assembly
- Which tests apply only to prototypes or first articles
- Required test limits
- Test duration
- Test voltage or current
- Fixture requirements
- Pass/fail criteria
- Whether measured results must be retained
- Whether reports must be supplied
- Whether testing must be tied to a serial number or lot
Testing costs can vary substantially depending on whether the manufacturer is performing basic continuity verification, developing a dedicated fixture or coordinating external environmental qualification.
XACT’s Cable Assembly Configuration Tool lets users identify IPC/WHMA-A-620, military standards, custom testing requirements, first-article needs and special certifications or approvals.
Related reading: How XACT Uses Vacuum Submersion Leak Testing
10. Specify Labeling, Marking and Traceability
Define how the assembly and its branches must be identified.
Requirements may include:
- Part-number labels
- Revision identification
- Serial numbers
- Lot numbers
- Connector identifiers
- Branch labels
- Circuit markers
- Orientation markings
- Date codes
- Customer asset numbers
- Barcodes or machine-readable labels
Include label content, location, orientation, material and durability requirements when controlled.
Also define the required traceability and documentation, such as:
- Material lot traceability
- Component lot traceability
- Build travelers
- Inspection records
- Test records
- Certificates of conformance
- First-article reports
- Calibration records
- Deviation approvals
- Revision history
These requirements affect production labor, systems and record retention, so they should be included before pricing.
11. Provide Prototype and Production Quantities
A quote should distinguish among:
- Engineering prototypes
- First-article units
- Pilot production
- Initial production order
- Expected annual usage
- Maximum release quantity
- Spare or replacement demand
Do not provide only an estimated annual quantity when the first order will be much smaller.
Suppliers may use different manufacturing methods, tooling and pricing structures for five prototypes than for 5,000 recurring units. Providing both initial and expected production quantities helps the manufacturer recommend an appropriate process.
Also state:
- Expected order frequency
- Forecast visibility
- Blanket-order requirements
- Inventory or stocking expectations
- Program duration
- Expected demand variability
12. Separate the Quote Deadline From the Delivery Requirement
“Need quote by” and “required delivery date” are different requirements.
Your RFQ should include:
- Date the quote is required
- Date prototypes are required
- Date production is required
- Whether the delivery date is fixed or preferred
- Whether partial deliveries are acceptable
- Required shipping location
- Expediting expectations
Avoid requesting an immediate quote while leaving no time for engineering review. Complex assemblies may require the manufacturer to clarify specifications, obtain component pricing, evaluate tooling and determine test requirements before providing a responsible quotation.
A fast quote based on unverified assumptions is not necessarily a better quote.
13. Identify Tooling and Nonrecurring Requirements
Some programs require one-time investments in:
- Overmold tooling
- Assembly fixtures
- Test fixtures
- Programming
- Engineering development
- Drawings
- First-article documentation
- Custom packaging
- Specialized crimp tooling
Ask suppliers to separate nonrecurring engineering and tooling costs from unit pricing.
Also clarify:
- Who owns the tooling
- Where it will be stored
- Whether maintenance is included
- Expected tooling life
- Whether replacement tooling is chargeable
- Whether the tooling can be transferred
- Which design files or documentation will be delivered
This prevents comparisons in which one supplier includes development and tooling while another excludes them.
14. Include Packaging and Delivery Requirements
Packaging can affect both quality and cost, particularly for long, delicate, labeled or contamination-sensitive assemblies.
Specify whether the assemblies require:
- Individual bags
- Protective caps
- Coiling diameter controls
- Reel packaging
- Custom trays
- Moisture protection
- Desiccant
- Clean packaging
- Branch separation
- Connector protection
- Kit packaging
- Customer-specific labels
- Export packaging
Also state whether assemblies must be delivered individually, in kits or grouped by installation location.
15. Upload the Most Useful Supporting Files
Include the clearest current version of every relevant document.
Useful files may include:
- Controlled drawings
- BOMs
- Wiring diagrams
- Pinout tables
- Connector specifications
- Equipment drawings
- Installation photographs
- Images of the existing assembly
- Customer specifications
- Test procedures
- Inspection requirements
- Packaging instructions
- Forecasts
- Samples or prior failure reports
Use clear file names and revision identifiers. Do not send several conflicting versions without identifying which one controls the quote.
When sending photographs, include a reference scale and show connector interfaces, branch points, labels and damaged areas when relevant.
Custom Cable Assembly RFQ Checklist
Before submitting the request, confirm that you have addressed the following:
Project and Application
- New or existing design
- Equipment type and assembly function
- Installation location
- Current design concerns
- Static or flexing use
Technical Package
- Drawing, sketch or sample
- Wiring diagram or pinout
- BOM or approved components
- Electrical requirements
- Mechanical dimensions and tolerances
- Connector orientation
- Labeling requirements
- Substitution policy
Environment
- Temperature range
- Moisture or submersion
- Chemical exposure
- UV exposure
- Vibration and impact
- Abrasion
- Flexing or movement
- Required sealing or protection level
Quality and Testing
- Workmanship standards
- Inspection requirements
- Production tests
- Qualification tests
- First-article requirements
- Certifications or approvals
- Traceability and documentation
Commercial Requirements
- Prototype quantity
- Initial production quantity
- Expected annual usage
- Quote deadline
- Required delivery date
- Packaging requirements
- Shipping location
- Tooling and nonrecurring-cost expectations
You do not need every item finalized to begin. Identify what is known, what is approximate and what requires supplier input.
Common RFQ Mistakes
Avoid these frequent problems:
- Providing a connector list without a pinout
- Giving annual usage without the initial order quantity
- Describing the assembly as “rugged” without defining the environment
- Requesting testing without pass/fail criteria
- Omitting the drawing revision
- Sending conflicting files
- Failing to identify mandatory components
- Leaving substitution rules unclear
- Treating the quote deadline as the delivery date
- Omitting tooling and first-article requirements
- Assuming documentation is included automatically
- Asking for a firm production price while major design decisions remain open
A quote based on incomplete information may still be useful for budgeting, but it should be clearly identified as preliminary and subject to revision.
Submit a Stronger Cable Assembly RFQ
A useful RFQ does not need to answer every engineering question. It must give the manufacturer enough context to understand the application, identify risk, expose assumptions and determine what still needs to be resolved.
XACT’s Cable Assembly Configuration Tool is designed for this early scoping stage. Users can select known build, manufacturing, termination, environmental and protection requirements; add engineering notes; and upload supporting files. XACT’s engineering team can then review the information and follow up on missing details.
Configure Your Cable Assembly With XACT
Share your known specifications, application requirements and available files. XACT can review the project for engineering fit, manufacturing approach, testing needs and quotation requirements.FAQ
Do I need a completed drawing to request a cable assembly quote?
No. A completed drawing is useful, but many projects can begin with a sample, pinout, wiring diagram, BOM, connector list, photographs or application requirements. The manufacturer may need additional engineering work before providing firm production pricing.
What is the minimum information needed for a cable assembly quote?
At minimum, provide the assembly’s function, connectors or termination points, electrical requirements, approximate dimensions, expected environment, quantity and delivery expectations. Clearly identify any unknown requirements.
Should I provide prototype and production quantities?
Yes. Prototype, pilot and recurring production quantities may require different tooling, processes and pricing. Include the expected first order and estimated annual demand.
Should the RFQ specify IPC/WHMA-A-620?
Specify it when required by the program. IPC/WHMA-A-620 defines practices and acceptance criteria for cable and wire harness assemblies, but buyers must still define product-specific design, inspection, testing and documentation requirements.
What environmental information should I provide?
Include temperature, moisture, submersion, chemicals, UV, abrasion, vibration, impact, pressure and movement conditions that apply. Use measurable ranges or referenced test requirements when available.
Can I request a quote for an existing assembly without its original documentation?
Potentially. Provide the physical sample, photographs, installation information and any known electrical or dimensional requirements. Reverse engineering, documentation and testing may need to be included as nonrecurring work.
Why do cable assembly quotes vary so much between suppliers?
Differences may result from materials, component sources, tooling, testing, documentation, assumed quantities, engineering scope, quality requirements and production location. Compare the assumptions and exclusions—not just the final unit price.
XACT’s Houston facility holds CAGE Code 8HHW8, and its Calgary facility holds CAGE Code L1030.